How To Clean A Fresco Air Purifier
Portable Electronic Air Purifier Cleaning Instructions
For the best cleaning feel utilise Platinum Air Care Jail cell Cleaner
Created using nature's blend of cleaners and degreasers to apace cutting through grease, grime, bacteria and viruses. Our environmentally safe cleaner uses no distillates, harsh alkalis, or butyl solvents, simply instead utilizes the potent cutting ability of natural citrus extracts to remove cell drove effortlessly. Our technicians apply this specific formula to service our customer'south units in their own home as well as in our service department.
Cleaning The Electronic Air Purifier
Electronic Air Cleaners work past electrically charging and collecting airborne contaminants. As these contaminants collect, the collector plates and Pre-Filter become extremely dirty with things like pet dander and dust. With an excess amount of contamination like whatsoever type of air filter, it will build up on the collector plates and the Pre-Filter, Electronic Air Cleaner'due south efficiency decreases.
Equally clay builds up, the snapping noise volition occur with great frequency. While in that location are many variations of Electronic Air Cleaners, this cleaning guide focuses on products with a like air cleaning method (Pre-Filter ➞ Electronic Cell ➞ Carbon/Five.O.C Filter) that Platinum Air Care offers today, and in the past such as Saviair 5000, RespirAide 400T (and the older RespirAide 200T and RespirAide 300T models) and the RPS 600S.
To prevent the loss of efficiency, the Electronic Cell and Pre-Filter must be cleaned regularly. How oft volition depend on the usage. Variables, such as number of occupants, pets, and fume determine how oftentimes the Air Cleaner requires cleaning. Cleaning once every iii to 6 months for non-smokers, and once a month for smokers is recommended for maximum benefit of your product.
Before Starting:
About units have automatic shutoff, however we recommend powering off and unplugging your unit.
Cleaning The Pre-Filter:
Remove the Pre-Filter and vacuum the accumulated grit and lint. Washing the Pre-Filter one time a month is recommended (you tin use electronic cell cleaner if desired). A thorough rinsing is required after each cleaning. Allow Pre-Filter to completely dry before placing back inside the unit of measurement.
To admission the Pre-Filter, open the front panel by pulling from the handle slots as pictured (some models may vary).
Slide the Pre-Filter out from the tiptop as pictured.
Cleaning The Electronic Prison cell:
While the front panel door is open up, remove the Electronic Prison cell from the air cleaner. Exist careful not to bend or blindside the cell or it's collecting plates. If the cell is extremely dirty, it's recommended to lightly rinse off the cell outdoors using a hose.
Submerge the unabridged cell in warm to hot h2o for 5 minutes (nosotros use the laundry tub). Remove the cell from the water and spray cell down thoroughly with Electronic Cell Cleaner Fluid (Such every bit Platinum Air Care Cell Cleaner). Allow the spray to sit on the prison cell for 5 minutes. Change the water in the tub, and then submerge the jail cell in fresh warm to hot water for another 5 minutes.
Rinse, milkshake out, and allow the prison cell to completely dry out over night. If you put the unit back together while the cell or filters are nevertheless wet, serious arcing and snapping noise will occur. Using a hair dryer can be used to speed up drying time, yet information technology is nonetheless recommended to let the cell sit and dry over night.
RespirAide Series and RPS600S Units:
Slide forward the jail cell frame and carefully lift the jail cell from the handle equally shown below:
RPS 600SL Units: At that place is no sliding frame; to remove the cell yous must open the prison cell blocking tabs by rotating them to the inside.
RPS 600SL Units: After rotating the tabs, carefully remove the cell from the unit as shown below:
Warning!
Practice non wash collecting cell in a dishwasher. Never utilize any object to clean between the cell plates (such every bit a scrubbing brush) as this may cause damage to the cell collecting plates or ionizing wires. Never place the electronic cell in an oven to dry.
The Activated Carbon V.O.C (Volatile Organic Chemical compound) Filter:
Recommended Replacement: Every half dozen months or every 2-4 months in smoking environments.
The Activated Carbon Five.O.C (Volatile Organic Chemical compound) Filter is not a washable filter and must be replaced every vi months, or every 2-4 months in smoking environments to ensure maximum effectiveness. The odor absorption capabilities of the carbon filter last between 2 and 6 months. In one case the carbon filter can no longer remove odors from the air, the carbon filter will need to be replaced. Information technology is NOT recommended to leave the carbon filter in the machine for longer than vi months without replacement.
RespirAide serial and RPS 600S units: Just every bit the Pre-Filter and Electronic Cell were removed, the Carbon Filter is accessed behind the Cell. Slide the Carbon Filter out by property the top of it and lifting upwardly as pictured below:
RPS 600SL Units: The Carbon Filter is accessible merely once the Pre-Filter and Electronic Cell are removed. Remove the Carbon Filter by grabbing the tab then unhooking the filter from it's holder as shown beneath:
Photocatalytic Chamber and Ultra-Violet (UV) Lamp Replacement:
Recommended Ultra-Violet Lamp Replacement: In one case Per Year
Once you have removed all of the filters (The Pre-Filter, Electronic Prison cell, and the V.O.C/Carbon Filter) you volition now accept access to the Ultra-Violet Lamp and Photocatalytic chamber area.
The Photocatalytic chamber/filter is a permanent filter. The simply necessary maintenance for this filter is to keep the area dust gratuitous if a build-up has accumulated. You tin clean this filter by gently vacuuming it with a vacuum soft bristle brush. Practise Not remove or wash this filter.
The Ultra-Violet Type-C (UV-C) Lamp has a life expectancy of ane year. Once 1 yr has past, the effectiveness of the UVC lamp will drop, it is recommended to supplant the UV lamps once per year. The RespirAide and RPS serial units have UV lamp indicator lights; this light volition flash indicating a replacement is required. Caution: Practice NOT touch the glass portion of the lamp.
Replacing the UV lamps can be a delicate process, if you are not confident we recommend scheduling a Platinum Air Care technician to do the replacement for y'all, our technician can guide and teach you how to practise this yourself in person.
The RespirAide 400T, RPS 600S and RPS 600SL units feature dual ultra-violet lamps on both the left and correct side of the Photocatalytic chamber. To remove the UV lamps, carefully grab the stop portions of the lamps (usually a white plastic) and twist to "unlock" it's connection. The lamp should then feel loose and be like shooting fish in a barrel to remove. You tin now supplant the ultra-violet lamps with new ones.
Reassembling and Resetting The Unit of measurement:
Once yous accept finished cleaning and replacing your filters on the select unit, and have made sure all parts are thoroughly dry, you can at present reassemble the unit the same way you lot had disassembled information technology.
To make your unit aware that it has been cleaned, press and concur the ability button for iii seconds (some models may take longer to reset, for example holding the power button for 15 seconds or more than). When the unit has reset, you lot should hear a beep and come across all lights flash (other models may vary, please consult your manual or contact united states of america directly for additional help). Now that your unit has been reset, it is ready to make clean the air!
Troubleshooting The Air Purifier:
If your air purifier is non starting, or if the air purifier is showing error lights double-cheque with the steps above; specifically the following:
-
If the air purifier is not turning on, brand sure information technology is correctly re-assembled afterwards you cleaned it (this is mainly regarding the filter door), and as well make sure the unit is plugged back into the power outlet (double-check both the wall plug and if the power cord is inserted correctly into the back of the air purifier)
-
If the air purifier's maintenance lights are still on or flashing, try unplugging the unit, and plugging information technology dorsum in once again. Plough information technology on and reset the unit of measurement in one case or even twice using the included remote control.
Need additional support?
If yous need electronic air purifier service contact Platinum Air Intendance by filling out the form below or calling (519) 686-3595 | Cost Free 1 (877) 339-4701
Source: https://www.platinumaircare.ca/service/electronic-air-purifier-cleaning-instructions